# Temperature & Humidity Sensor Evaluation and Testing
|
|
|
|
|
|
|
|
| Metric | [HTU21D](https://octopart.com/htu21d-measurement+specialties-30374934) |[Si72021](https://octopart.com/si7021-a20-im-silicon+labs-52675246)| DHT22 | DHT22 vs HTU21D Difference| [BME280](https://octopart.com/bme280-bosch-52931981) |
|
|
| ------------- | ------------- |------------- | ------------- | ------------- | ------------- |
|
|
| Cost in 1k off | £1.42 (July16) |£2.15| £4.57 (July16) | 3.2 times cheaper (£3.15 less!) | £3.07 |
|
|
| Vcc | 2.1v - 3.6V | 1.9V - 3.6V | 3.3-6V | | 1.71 V - 3.6V |
|
|
| Humidity accuracy | ±2% RH | ±2% RH | ±2%RH | n/a | ±3%RH |
|
|
| Humidity Range | 0-100% RH | 0-100% RH | 0-100% RH | n/a| 0-100% RH |
|
|
| Temperature accuracy | ±0.3°C | ±0.4°C| ±0.5°C | 40% more accurate | ±0.5 - ±1.0 |
|
|
| Temperature Range | -40°C +125°C | -40°C +125°C | -40°C +80°C | 56% more accurate | -40°C +80°C |
|
|
| Sleep Current | 0.02uA | 0.06uA | 15uA | 750 times less power | 0.1uA - 0.3uA |
|
|
| Measurement Current | 0.045mA | 0.09 mA | 0.5mA | 11 times less power | 0.714mA - 0.350mA |
|
|
| Measurement time | 0.01s - 0.0026s | 0.01s - 0.0026s | 2s | 200 times faster | 0.013s |
|
|
| Energy consumed per sample | 0.00045mW || 1mW | 2222 times less power | |
|
|
| Time sampling per day* | 14.4s || 2800s | | |
|
|
| Time sleeping per day* | 86386s || 83600s | | |
|
|
| Energy consumed per day* | 2.36mW [1] || 2836mW [2] | 1201 times less energy per day! | |
|
|
|
|
|
|
## Energy consumed per day*
|
|
|
|
- **HTU21D:** (14.4s * 0.045mA) + (86386 * 0.00002mA) = 0.63mW + 1.73mW = **2.36mW** [1]
|
|
- **DHT22:** (2800s * 0.55mA) + (86386 * 0.015mA) = 1540mW + 1295.8mW = **2836mW** [2]
|
|
|
|
\*Assuming 1 sample per min and sleeping in between samples, 1440 min per day = 86400s per day
|
|
|
|
[Adafruit HTU21D Library](https://github.com/adafruit/Adafruit_HTU21DF_Library)
|