Compare commits

...

2 Commits
1.0.1 ... main

Author SHA1 Message Date
Simon 289afca88d Added exeption for all reading 2023-03-20 08:58:39 +01:00
Simon fbe885b92c Added Phase A_B_C data and changed intervall 2023-03-17 14:20:05 +01:00
2 changed files with 47 additions and 44 deletions

View File

@ -20,6 +20,9 @@ class ReadRegister:
rn.PV_02_VOLTAGE,
rn.PV_01_CURRENT,
rn.PV_02_CURRENT,
rn.PHASE_A_CURRENT,
rn.PHASE_B_CURRENT,
rn.PHASE_C_CURRENT,
rn.INPUT_POWER,
rn.ACTIVE_POWER,
rn.GRID_CURRENT,

View File

@ -22,7 +22,7 @@ port = os.getenv("INVERTER_PORT", 502)
host = os.getenv("INVERTER_HOST", "192.168.200.100")
LOGGER = logging.getLogger(__name__)
REQUEST_INTERVAL = 60
REQUEST_INTERVAL = 10
async def get_inverter_client() -> AsyncHuaweiSolar:
@ -41,52 +41,52 @@ async def main():
status = await inverter_client.get(
ReadRegister.inverter_reg_status, slave_id
)
LOGGER.info(f"-- INVERTER -- Status: {status}")
if (
status.value == rv.DEVICE_STATUS_DEFINITIONS.get(0x0200)
or FORCE_GET
): # Inverter is active, Get data
LOGGER.info("-- INVERTER -- Send measured values")
for register in ReadRegister.reg_to_read_measured:
result = await get_inverter_data(inverter_client, register)
send_data(
mqtt_client,
format_data_to_serialized_json(result),
f"measure/{result.name}",
)
if count == 6: # Every 1 min
LOGGER.info("-- INVERTER -- Send calculated values")
for register in ReadRegister.reg_to_read_calculated:
result = await get_inverter_data(inverter_client, register)
send_data(
mqtt_client,
format_data_to_serialized_json(result),
f"calculated/{result.name}",
)
if count == 30: # Every 5 min
LOGGER.info("-- INVERTER -- Send status/alarm")
for register in ReadRegister.reg_to_read_status:
result = await get_inverter_data(inverter_client, register)
send_data(
mqtt_client,
format_data_to_serialized_json(result),
f"status/{result.name}",
)
count = 0
else:
LOGGER.debug("-- INVERTER -- Not Active, No need to read values")
count += 1
LOGGER.info(f"Sleeping {REQUEST_INTERVAL}")
await asyncio.sleep(REQUEST_INTERVAL)
except ReadException as error:
LOGGER.error(f"Can't read register, {ReadRegister.inverter_reg_status}. "
f"Error code: {error}. Sleep for 10 min")
await asyncio.sleep(10*60)
LOGGER.info(f"-- INVERTER -- Status: {status}")
if (
status.value == rv.DEVICE_STATUS_DEFINITIONS.get(0x0200)
or FORCE_GET
): # Inverter is active, Get data
LOGGER.info("-- INVERTER -- Send measured values")
for register in ReadRegister.reg_to_read_measured:
result = await get_inverter_data(inverter_client, register)
send_data(
mqtt_client,
format_data_to_serialized_json(result),
f"measure/{result.name}",
)
LOGGER.info("-- INVERTER -- Send calculated values")
for register in ReadRegister.reg_to_read_calculated:
result = await get_inverter_data(inverter_client, register)
send_data(
mqtt_client,
format_data_to_serialized_json(result),
f"calculated/{result.name}",
)
if count == 5:
LOGGER.info("-- INVERTER -- Send status/alarm")
for register in ReadRegister.reg_to_read_status:
result = await get_inverter_data(inverter_client, register)
send_data(
mqtt_client,
format_data_to_serialized_json(result),
f"status/{result.name}",
)
count = 0
else:
LOGGER.debug("-- INVERTER -- Not Active, No need to read values")
count += 1
LOGGER.info(f"Sleeping {REQUEST_INTERVAL}")
await asyncio.sleep(REQUEST_INTERVAL)
await asyncio.sleep(60) # Sleep 1 min
def send_data(