Docker/evcc/evcc.yaml

134 lines
3.2 KiB
YAML

sponsortoken: eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJleHAiOjE3ODEzODIyNTYsImlhdCI6MTY4Njc3NDI1NiwiaXNzIjoiZXZjYy5pbyIsInN1YiI6Im1pbHZlcnQifQ.HUEmc0NSPt9x5MbOHUAGU6bp3H3E3qwu6O6BAHH9FvE
#log: debug
#levels:
# easee: trace
interval: 30s
vehicles:
- name: car
type: custom
title: id4
capacity: 79 # kWh
soc:
source: mqtt
topic: weconnect/0/vehicles/WVGZZZE2ZPE051949/domains/fuelStatus/rangeStatus/primaryEngine/currentSOC_pct
range:
source: mqtt
topic: weconnect/0/vehicles/WVGZZZE2ZPE051949/domains/fuelStatus/rangeStatus/primaryEngine/remainingRange_km
onIdentify: # set defaults when vehicle is identified
mode: pv # enable PV-charging when vehicle is identified
minSoC: 20 # immediately charge to 0% regardless of mode unless "off" (disabled)
targetSoC: 90 # limit charge to 90%
chargers:
- name: wallbox
type: easee
user: simon+easee@milvert.com
password: X7#aEzjlEysBgl
charger: EHCNF485
loadpoints:
- title: Garage
charger: wallbox
vehicle: car
mode: pv
phases: 3
mincurrent: 6
maxcurrent: 16
resetOnDisconnect: True
enable:
threshold: 0
delay: 15s
disable:
threshold: 500
delay:
2m
site:
title: Hemma
meters:
pv:
- pv
grid: my_grid
meters:
- name: pv
type: custom
power:
source: mqtt
topic: inverter/measure/active_power
jq: .value
energy:
source: mqtt
topic: inverter/calculated/accumulated_yield_energy
jq: .value
timeout: 1h
currents:
- source: mqtt
topic: inverter/measure/phase_A_current
jq: .value
- source: mqtt
topic: inverter/measure/phase_B_current
jq: .value
- source: mqtt
topic: inverter/measure/phase_C_current
jq: .value
- name: my_grid
type: custom
power:
source: calc
add:
- source: mqtt
topic: dsmr/reading/electricity_currently_returned
scale: -1000
- source: mqtt
topic: dsmr/reading/electricity_currently_delivered
scale: 1000
energy:
source: calc
add:
- source: mqtt
topic: dsmr/reading/electricity_returned
scale: 0.001
- source: mqtt
topic: dsmr/reading/electricity_delivered
scale: -0.001
currents:
- source: calc
add:
- source: mqtt
topic: dsmr/reading/phase_currently_delivered_l1
scale: -1
- source: mqtt
topic: dsmr/reading/phase_currently_returned_l1
- source: calc
add:
- source: mqtt
topic: dsmr/reading/phase_currently_delivered_l2
scale: -1
- source: mqtt
topic: dsmr/reading/phase_currently_returned_l2
- source: calc
add:
- source: mqtt
topic: dsmr/reading/phase_currently_delivered_l3
scale: -1
- source: mqtt
topic: dsmr/reading/phase_currently_returned_l3
influx:
url: http://influx:8086
database: Car
token: H7m068KDh84kcmmkz3fy-dEsKoeYv90rnNXIidPZoBy240Jzdbr2uDtGveiuDz4rGK4jmMI8J00zVwgIBYJxXA==
org: milvert
mqtt:
broker: mqtt:1883
user: simon
password: bajsa123
topic: evcc