Docker/evcc/evcc.yaml

144 lines
3.3 KiB
YAML

sponsortoken: eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJpc3MiOiJldmNjLmlvIiwic3ViIjoibWlsdmVydCIsImV4cCI6MTgzMDE5MzIwMCwiaWF0IjoxNzM1NTg1MjAwLCJzcmMiOiJnaCJ9._K23QsA15DIHRjujwH8rnFZyloSw1RPIeIS4W5WLFGE
log: error
levels:
tariff: trace
interval: 30s
vehicles:
- name: car
type: custom
title: id4
capacity: 79 # kWh
soc:
source: mqtt
topic: weconnect/0/vehicles/WVGZZZE2ZPE051949/domains/charging/batteryStatus/currentSOC_pct
range:
source: mqtt
topic: weconnect/0/vehicles/WVGZZZE2ZPE051949/domains/fuelStatus/rangeStatus/primaryEngine/remainingRange_km
odometer:
source: mqtt
topic: weconnect/0/vehicles/WVGZZZE2ZPE051949/domains/measurements/odometerStatus/odometer
climater:
source: go
vm: shared
script: |
remoteClimateState != "off"
in:
- name: remoteClimateState
type: string
config:
source: mqtt
topic: weconnect/0/vehicles/WVGZZZE2ZPE051949/domains/climatisation/climatisationStatus/climatisationState
chargers:
- name: wallbox
type: easee
user: simon+easee@milvert.com
password: X7#aEzjlEysBgl
charger: EHCNF485
circuits:
- name: main # if there is only one circuit defined the name needs to be 'main'
title: 'main circuit' # name for the UI (not implemented in UI yet)
maxCurrent: 20
maxPower: 10000
meter: my_grid # optiona
loadpoints:
- title: Garage
charger: wallbox
vehicle: car
circuit: main
mode: pv
phases: 3
enable:
threshold: 0
delay: 15s
disable:
threshold: 500
delay:
2m
site:
title: Hemma
meters:
pv:
- pv
grid: my_grid
meters:
- name: pv
type: custom
power:
source: mqtt
topic: inverter/measure/active_power
# jq: .value
energy:
source: mqtt
topic: inverter/calculated/accumulated_yield_energy
timeout: 60s
currents:
- source: mqtt
topic: inverter/measure/phase_A_current
timeout: 60s
# jq: .value
- source: mqtt
topic: inverter/measure/phase_B_current
timeout: 60s
# jq: .value
- source: mqtt
topic: inverter/measure/phase_C_current
timeout: 60s
- name: my_grid
type: custom
power:
source: calc
add:
- source: mqtt
topic: dsmr/reading/electricity_currently_returned
scale: -1000
timeout: 30s
- source: mqtt
topic: dsmr/reading/electricity_currently_delivered
scale: 1000
timeout: 30s
energy:
source: calc
add:
- source: mqtt
topic: dsmr/reading/electricity_returned_1
scale: 0.001
timeout: 30s
- source: mqtt
topic: dsmr/reading/electricity_delivered_1
scale: -0.001
timeout: 30s
currents:
- source: mqtt
topic: dsmr/reading/phase_power_current_l1
timeout: 30s
- source: mqtt
topic: dsmr/reading/phase_power_current_l2
timeout: 30s
- source: mqtt
topic: dsmr/reading/phase_power_current_l1
timeout: 30s
influx:
url: http://influx:8086
database: Car
token: H7m068KDh84kcmmkz3fy-dEsKoeYv90rnNXIidPZoBy240Jzdbr2uDtGveiuDz4rGK4jmMI8J00zVwgIBYJxXA==
org: milvert
mqtt:
broker: mqtt:1883
user: simon
password: bajsa123
topic: evcc