144 lines
3.3 KiB
YAML
144 lines
3.3 KiB
YAML
sponsortoken: eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJpc3MiOiJldmNjLmlvIiwic3ViIjoibWlsdmVydCIsImV4cCI6MTgzMDE5MzIwMCwiaWF0IjoxNzM1NTg1MjAwLCJzcmMiOiJnaCJ9._K23QsA15DIHRjujwH8rnFZyloSw1RPIeIS4W5WLFGE
|
|
|
|
log: error
|
|
levels:
|
|
tariff: trace
|
|
|
|
interval: 30s
|
|
|
|
vehicles:
|
|
- name: car
|
|
type: custom
|
|
title: id4
|
|
capacity: 79 # kWh
|
|
soc:
|
|
source: mqtt
|
|
topic: weconnect/0/vehicles/WVGZZZE2ZPE051949/domains/charging/batteryStatus/currentSOC_pct
|
|
range:
|
|
source: mqtt
|
|
topic: weconnect/0/vehicles/WVGZZZE2ZPE051949/domains/fuelStatus/rangeStatus/primaryEngine/remainingRange_km
|
|
odometer:
|
|
source: mqtt
|
|
topic: weconnect/0/vehicles/WVGZZZE2ZPE051949/domains/measurements/odometerStatus/odometer
|
|
climater:
|
|
source: go
|
|
vm: shared
|
|
script: |
|
|
remoteClimateState != "off"
|
|
in:
|
|
- name: remoteClimateState
|
|
type: string
|
|
config:
|
|
source: mqtt
|
|
topic: weconnect/0/vehicles/WVGZZZE2ZPE051949/domains/climatisation/climatisationStatus/climatisationState
|
|
|
|
|
|
chargers:
|
|
- name: wallbox
|
|
type: easee
|
|
user: simon+easee@milvert.com
|
|
password: X7#aEzjlEysBgl
|
|
charger: EHCNF485
|
|
|
|
circuits:
|
|
- name: main # if there is only one circuit defined the name needs to be 'main'
|
|
title: 'main circuit' # name for the UI (not implemented in UI yet)
|
|
maxCurrent: 20
|
|
maxPower: 10000
|
|
meter: my_grid # optiona
|
|
|
|
loadpoints:
|
|
- title: Garage
|
|
charger: wallbox
|
|
vehicle: car
|
|
circuit: main
|
|
mode: pv
|
|
phases: 3
|
|
enable:
|
|
threshold: 0
|
|
delay: 15s
|
|
disable:
|
|
threshold: 500
|
|
delay:
|
|
2m
|
|
|
|
site:
|
|
title: Hemma
|
|
meters:
|
|
pv:
|
|
- pv
|
|
grid: my_grid
|
|
|
|
meters:
|
|
- name: pv
|
|
type: custom
|
|
power:
|
|
source: mqtt
|
|
topic: inverter/measure/active_power
|
|
# jq: .value
|
|
energy:
|
|
source: mqtt
|
|
topic: inverter/calculated/accumulated_yield_energy
|
|
timeout: 60s
|
|
currents:
|
|
- source: mqtt
|
|
topic: inverter/measure/phase_A_current
|
|
timeout: 60s
|
|
# jq: .value
|
|
- source: mqtt
|
|
topic: inverter/measure/phase_B_current
|
|
timeout: 60s
|
|
# jq: .value
|
|
- source: mqtt
|
|
topic: inverter/measure/phase_C_current
|
|
timeout: 60s
|
|
|
|
- name: my_grid
|
|
type: custom
|
|
power:
|
|
source: calc
|
|
add:
|
|
- source: mqtt
|
|
topic: dsmr/reading/electricity_currently_returned
|
|
scale: -1000
|
|
timeout: 30s
|
|
- source: mqtt
|
|
topic: dsmr/reading/electricity_currently_delivered
|
|
scale: 1000
|
|
timeout: 30s
|
|
energy:
|
|
source: calc
|
|
add:
|
|
- source: mqtt
|
|
topic: dsmr/reading/electricity_returned_1
|
|
scale: 0.001
|
|
timeout: 30s
|
|
- source: mqtt
|
|
topic: dsmr/reading/electricity_delivered_1
|
|
scale: -0.001
|
|
timeout: 30s
|
|
|
|
currents:
|
|
- source: mqtt
|
|
topic: dsmr/reading/phase_power_current_l1
|
|
timeout: 30s
|
|
- source: mqtt
|
|
topic: dsmr/reading/phase_power_current_l2
|
|
timeout: 30s
|
|
- source: mqtt
|
|
topic: dsmr/reading/phase_power_current_l1
|
|
timeout: 30s
|
|
|
|
|
|
influx:
|
|
url: http://influx:8086
|
|
database: Car
|
|
token: H7m068KDh84kcmmkz3fy-dEsKoeYv90rnNXIidPZoBy240Jzdbr2uDtGveiuDz4rGK4jmMI8J00zVwgIBYJxXA==
|
|
org: milvert
|
|
|
|
mqtt:
|
|
broker: mqtt:1883
|
|
user: simon
|
|
password: bajsa123
|
|
topic: evcc
|