sponsortoken: eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJleHAiOjE3ODEzODIyNTYsImlhdCI6MTY4Njc3NDI1NiwiaXNzIjoiZXZjYy5pbyIsInN1YiI6Im1pbHZlcnQifQ.HUEmc0NSPt9x5MbOHUAGU6bp3H3E3qwu6O6BAHH9FvE log: error #levels: # car: trace interval: 30s vehicles: - name: car type: custom title: id4 capacity: 79 # kWh soc: source: mqtt topic: weconnect/0/vehicles/WVGZZZE2ZPE051949/domains/charging/batteryStatus/currentSOC_pct range: source: mqtt topic: weconnect/0/vehicles/WVGZZZE2ZPE051949/domains/fuelStatus/rangeStatus/primaryEngine/remainingRange_km odometer: source: mqtt topic: weconnect/0/vehicles/WVGZZZE2ZPE051949/domains/measurements/odometerStatus/odometer climater: source: go vm: shared script: | remoteClimateState != "off" in: - name: remoteClimateState type: string config: source: mqtt topic: weconnect/0/vehicles/WVGZZZE2ZPE051949/domains/climatisation/climatisationStatus/climatisationState chargers: - name: wallbox type: easee user: simon+easee@milvert.com password: X7#aEzjlEysBgl charger: EHCNF485 loadpoints: - title: Garage charger: wallbox vehicle: car mode: pv phases: 3 mincurrent: 6 maxcurrent: 16 enable: threshold: 0 delay: 15s disable: threshold: 500 delay: 2m site: title: Hemma meters: pv: - pv grid: my_grid meters: - name: pv type: custom power: source: mqtt topic: inverter/measure/active_power # jq: .value energy: source: mqtt topic: inverter/calculated/accumulated_yield_energy # jq: .value timeout: 1h currents: - source: mqtt topic: inverter/measure/phase_A_current # jq: .value - source: mqtt topic: inverter/measure/phase_B_current # jq: .value - source: mqtt topic: inverter/measure/phase_C_current # jq: .value - name: my_grid type: custom power: source: calc add: - source: mqtt topic: dsmr/reading/electricity_currently_returned scale: -1000 - source: mqtt topic: dsmr/reading/electricity_currently_delivered scale: 1000 energy: source: calc add: - source: mqtt topic: dsmr/reading/electricity_returned_1 scale: 0.001 - source: mqtt topic: dsmr/reading/electricity_delivered_1 scale: -0.001 currents: - source: calc add: - source: mqtt topic: dsmr/reading/phase_currently_delivered_l1 scale: -1 - source: mqtt topic: dsmr/reading/phase_currently_returned_l1 - source: calc add: - source: mqtt topic: dsmr/reading/phase_currently_delivered_l2 scale: -1 - source: mqtt topic: dsmr/reading/phase_currently_returned_l2 - source: calc add: - source: mqtt topic: dsmr/reading/phase_currently_delivered_l3 scale: -1 - source: mqtt topic: dsmr/reading/phase_currently_returned_l3 influx: url: http://influx:8086 database: Car token: H7m068KDh84kcmmkz3fy-dEsKoeYv90rnNXIidPZoBy240Jzdbr2uDtGveiuDz4rGK4jmMI8J00zVwgIBYJxXA== org: milvert mqtt: broker: mqtt:1883 user: simon password: bajsa123 topic: evcc